Description
Modine Commercial Workspace Heater – 200K BTU/Intermittent Pilot Ignition/LP/Single Stage w/Aluminized Steel Heat Exchanger & Burner
The Modine Commercial LP Workspace Heater is your dependable solution for keeping garages, workshops, studios, and other smaller commercial spaces warm and comfortable throughout the winter. This industrial-grade heater boasts a dependable 200,000 BTU output, efficiently heating your workspace and ensuring a consistent and comfortable environment. Fueled by Liquid Propane (LP), this heater offers versatility for businesses that rely on readily available fuel sources.
Features
-
Made in the USA
-
83% thermal efficiency, maximizing seasonal efficiency through the use of a collector box and the power exhauster
-
A power exhaust can rotate 180° allowing the unit to be vented vertically or horizontally
-
A 100% shut-off if the unit does not light, to ensure that unburned gases do not build up in the unit
-
An intermittent pilot-ignition system with continuous retry to keep the unit from locking and needing to be reset if the unit does not light on the first try
-
All PDP/BDP units can be field-converted from natural gas to propane if desired
-
A safety pressure-switch monitors the vent pipe to assure flue gases leave the building and do not back up in the space
-
Designed to utilize the smallest-diameter vent pipe possible
-
“Wing” screws so that the bottom pan can be dropped without a screwdriver or nut driver
-
A level hanging mechanism for easy field adjustments after adding accessories that may change the unit’s center of gravity
-
Draws combustion air from inside the workspace
-
6″ vent connection
-
Liquid Propane
-
200,000 BTU
-
Intermittent Pilot Ignition
-
Single stage – on/off operation
-
Aluminized steel heat exchanger & burner
Specifications
| Fuel Type | Propane |
|---|---|
| Control Type | Electronic/IPI |
| Color/Finish | Gray |
| Size | 25.63″W x 40.25″T x 34.88″D |
What Our Experts Think
The Modine Commercial Workspace Heater – 200K BTU with Intermittent Pilot Ignition, LP (Liquefied Petroleum) gas, Single Stage operation, and Aluminized Steel Heat Exchanger & Burner is a cost-effective and efficient heating solution for medium to large commercial and industrial spaces. Here’s why it’s a great option:
- Effective Heating Capacity: Delivers 200,000 BTUs, making it ideal for heating workshops, warehouses, and larger commercial environments.
- Intermittent Pilot Ignition: Ensures reliable and efficient ignition with reduced fuel consumption, improving overall energy efficiency.
- LP (Liquefied Petroleum) Gas-Powered: Provides flexibility in areas where natural gas isn’t available, ideal for remote or off-grid locations.
- Single-Stage Operation: Simple and easy-to-use, with dependable performance and minimal maintenance.
- Aluminized Steel Heat Exchanger: Built for durability, corrosion resistance, and long-lasting performance in harsh environments.
- Aluminized Steel Burner: Ensures efficient combustion and consistent heat output, even under heavy use.
- Energy Efficient: Combines intermittent pilot ignition with optimized combustion for fuel savings and reduced emissions.
- Durable Construction: Made with high-quality materials designed to withstand the demands of commercial and industrial applications.
- Flexible Installation: Compact design allows for wall or ceiling mounting, optimizing space in commercial workspaces.
Q&A
Q: What is the Modine Commercial Workspace Heater 200K BTU LP?
A: The Modine 200K BTU LP workspace heater is a propane-powered heating solution designed for commercial and industrial spaces, such as warehouses and workshops. It features intermittent pilot ignition, a single-stage operation, and a durable aluminized steel heat exchanger and burner for efficient and reliable heating.
Q: What are its key features?
A: Key features include:
- 200,000 BTU output: Provides effective heating for medium to large commercial spaces.
- Intermittent pilot ignition: Efficiently ignites gas only when needed, reducing fuel consumption.
- Single-stage operation: Delivers consistent and straightforward heating performance.
- Aluminized steel heat exchanger: Offers corrosion resistance and long-lasting durability for effective heat transfer.
- Aluminized steel burner: Ensures reliable combustion and efficient heat distribution.
Q: What are the benefits of the aluminized steel heat exchanger and burner?
A: Aluminized steel components provide excellent corrosion resistance, durability, and efficient heat transfer, making them ideal for harsh commercial environments.
Q: How does intermittent pilot ignition improve efficiency?
A: The intermittent pilot ignition system only ignites gas when the heater is draftly operating, reducing fuel waste and improving overall energy efficiency.
Q: Is this heater energy-efficient?
A: Yes, the combination of intermittent pilot ignition, aluminized steel components, and effective heat output with minimal fuel consumption enhances energy efficiency.
Q: Why choose the Modine 200K BTU LP Heater?
A: Its durable construction, reliable ignition system, and energy-efficient heating make it ideal for commercial spaces that need dependable, cost-effective, and long-lasting heating solutions.
Maintenance Tips
- Daily Cleaning: Wipe down the heater exterior to remove dust, dirt, and debris.
- Inspect Heat Exchanger: Check the aluminized steel heat exchanger for corrosion, dirt buildup, or damage. Clean periodically to maintain efficient heat transfer.
- Burner Maintenance: Regularly inspect the aluminized steel burner for soot or debris buildup. Clean it as needed to ensure optimal combustion.
- Ignition System Check: Test the intermittent pilot ignition system to ensure reliable and consistent operation.
- Inspect LP Gas Connections: Use a soapy water solution to check for leaks in LP gas fittings and connections.
- Exhaust Venting: Ensure the exhaust vent system is clear of blockages or leaks to safely expel combustion gases.
- Air Filter Maintenance: Replace or clean air filters regularly to ensure proper airflow.
- Condensate Drain Cleaning: If applicable, inspect and clear the condensate drain to prevent clogs.
- Seasonal Maintenance: Schedule professional servicing at least once a year to ensure safe and efficient operation.
- Safety System Test: Verify that the emergency shutoff system works properly in case of malfunction.